New Updated 2V0-621D Exam Questions from PassLeader 2V0-621D PDF dumps! Welcome to download the newest PassLeader 2V0-621D VCE dumps: http://www.passleader.com/2v0-621d.html (256 Q&As)
Keywords: 2V0-621D exam dumps, 2V0-621D exam questions, 2V0-621D VCE dumps, 2V0-621D PDF dumps, 2V0-621D practice tests, 2V0-621D study guide, 2V0-621D braindumps, VMware Certified Professional 6 – Data Center Virtualization Delta Exam
P.S. New 2V0-621D dumps download from Google Drive: https://drive.google.com/open?id=0B-ob6L_QjGLpRDdvZTNjQUdZYUE
P.S. New 2V0-621 dumps download from Google Drive: https://drive.google.com/open?id=0B-ob6L_QjGLpRXc3YlBETEM3ODQ
NEW QUESTION 240
An administrator has a virtual machine (VM) that uses a shared USB device. Which option will allow the VM to utilize vMotion while retaining the maximum possible functionality?
A. Disable the USB device from the VM.
B. Configure the VM to support vMotion while the device is connected.
C. Enable migration support for the individual USB device.
D. Remove the device from the VM.
Answer: B
NEW QUESTION 241
An administrator is configuring an identity source for Single Sign-On. The administrator will use the machine that Single Sign-On is running on, but does not want all users on the machine to be visibile to SSO. Which Identity Source meets this requirement?
A. Active Directory (Integrated Windows Authentication)
B. Active Directory as an LDAP Service
C. OpenLDAP
D. LocalOS
Answer: A
NEW QUESTION 242
Which two conditions would prevent an administrator from upgrading an existing vCenter Appliance to vSphere 6.x? (Choose two.)
A. The appliance has been configured to use an external Single Sign-On server.
B. The administrator did not export the appliance configuration.
C. The administrator is using an appliance with an embedded Platform Services Controller.
D. The ESXi Host that the appliance will run on has not been placed into Maintenance Mode.
Answer: AB
NEW QUESTION 243
An administrator has configured a cluster with the Host Failures Cluster Tolerates admission control policy, as shown in the Exhibit:
Based on the exhibit, which two statements are true? (Choose two.)
A. The number of slots per cluster node is four.
B. The cluster can sustain loss of only one node.
C. The number of slots per cluster node is three.
D. The cluster can sustain the loss of two nodes.
Answer: BC
NEW QUESTION 244
An administrator is creating a new Platform Service Controller Password Policy with the following requirements:
– Minimum length: Minimum of 8 characters
– Restrict use: 6
– Character requirements: At least one upper-case letter, one number, and one special character
– Identical adjacent characters: 0
When trying to assign the password “P@$$w0rd”, the administrator receives an error that the password does not meet the Password Policy requirements. Which part of the Password Policy does this password violate?
A. Minimum length
B. Restrict use
C. Character requirements
D. Identical adjacent characters
Answer: D
NEW QUESTION 245
Which two statements are true regarding upgrading from a Distributed vCenter Server 5.x to vCenter Server 6.x? (Choose two.)
A. vCenter Single Sign-on becomes part of the Platform Services Controller.
B. vCenter Inventory Service becomes part of the Platform Services Controller.
C. The vCenter Server service is not migrated during the upgrade process.
D. The vSphere License Service is migrated to the new vCenter Server 6.x instance.
Answer: AC
NEW QUESTION 246
An administrator wants to clone the configuration of an existing ESXi 6.x host to a new group of hosts, but does not want to clone storage specific settings. Which action would accomplish this?
A. Uncheck sub-profile
B. Remove sub-profile
C. Revert profile
D. Disable VM Storage Profile
Answer: B
NEW QUESTION 247
Which two statements are true regarding upgrading ESXi 6.x hosts using a USB flash drive? (Choose two.)
A. The ks.cfg file must be available to the ESXi 6.x host during bootup on a TFTP server.
B. The USB flash drive must be formatted using Fat32.
C. A partition table must be manually created on the USB flash device.
D. The USB flash drive must be mounted from a Windows device with sysconfig installed.
Answer: BC
NEW QUESTION 248
An administrator is configuring resource pools for a vSphere 6.x cluster. The cluster has these characteristics:
– Five ESXi 6.x hosts
– Six cores per host
– 70 virtual machines with 1 vCPU each
The administrator configures three resource pools and places the virtual machines into the pools, as follows:
– Production pool – High Share value with 40 virtual machines
– Infrastructure pool – Medium Share value with 20 virtual machines
– Development pool – Low Share value with 10 virtual machines
Given this configuration, what is the expected performance for each group of virtual machines during contention?
A. Virtual machines in the Production pool will perform two times as well as those in the Infrastructure pool.
B. Virtual machines in the Infrastructure pool will perform four times as well as those in the Development pool.
C. Virtual machines in all resource pools will perform equally.
D. Virtual machines in the Development pool will perform two times as well as those in the Infrastructure pool.
Answer: C
NEW QUESTION 249
When operating with Distributed Resource Scheduler (DRS) and Distributed Power Management (DPM), what two statements explain the impact of disabling vSphere High Availability admission control? (Choose two.)
A. VMware DPM does not place hosts in standby mode if doing so would violate failover requirements.
B. DRS does not evacuate virtual machines from a host for the purpose of placing it in maintenance or standby modes if placing the host in this state would violate failover requirements.
C. DRS will evacuate virtual machines from hosts and places hosts in maintenance or standby modes regardless of the impact this might have on failover requirements.
D. VMware DPM will place hosts in standby mode even if doing so violates failover requirements.
Answer: CD
NEW QUESTION 250
An administrator is configuring Storage I/O Control. After enabling, the administrator notices high device latency and poor storage performance. Which two actions would likely reduce latency and improve functionality? (Choose two.)
A. Set the congestion threshold to 15ms
B. Set the congestion threshold value to 5ms
C. Ensure that each datastore has independent spindles
D. Ensure that each datastore uses shared spindles
Answer: AC
NEW QUESTION 251
……
Download the newest PassLeader 2V0-621D dumps from passleader.com now! 100% Pass Guarantee!
2V0-621D PDF dumps & 2V0-621D VCE dumps: http://www.passleader.com/2v0-621d.html (256 Q&As) (New Questions Are 100% Available and Wrong Answers Have Been Corrected! Free VCE simulator!)
P.S. New 2V0-621D dumps download from Google Drive: https://drive.google.com/open?id=0B-ob6L_QjGLpRDdvZTNjQUdZYUE
P.S. New 2V0-621 dumps download from Google Drive: https://drive.google.com/open?id=0B-ob6L_QjGLpRXc3YlBETEM3ODQ